DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 92
Bosch Security Systems | 8/04 | 4998153891C
Table 20: Zone Function Type Options (continued)
Zone Function Type Wiring
Configuration
Description Events/Reports
11
Controlled
Entry/Exit
Delay 1
Single EOL
Resistor
When control panel is On, short or open starts Entry Delay 1 if no
Trouble Option.
Follows Entry Delay 1 or 2. Follows Exit Delay.
If this Zone Function type is programmed for Trouble and a
trouble condition occurs when the control panel is armed, an
alarm event is generated. If a trouble condition occurs when the
control panel is disarmed, a trouble event is generated. Entry/Exit
Delay and Start Entry Delay settings are ignored for trouble
events.
Tamper-Wired,
Zone-Doubled,
No EOL Resistor
When control panel is On, fault starts Entry Delay 1 if no Trouble
Option.
Follows Entry Delay 1 or 2. Follows Exit Delay.
If this Zone Function type is programmed for Trouble and a
trouble condition occurs when the control panel is armed, an
alarm event is generated. If a trouble condition occurs when the
control panel is disarmed, a trouble event is generated. Entry/Exit
Delay and Start Entry Delay settings are ignored for trouble
events.
Alarm {8}, Cross Alarm {15}, Unverified
Cross {17}, Bypass {28,29}, Forced Pt
{32}, Swinger Shunt {33}, Unbypass
{35}, Swinger Shunt Restore {173},
Trouble {144}, Trouble Restore {151},
Missing Alarm {87}, Missing Trouble {88},
Restore from Alarm {117}, Restore from
Missing Alarm {175}, Restore from
Missing Trouble {176}
12
Controlled
Entry/Exit
Delay 2
Single EOL
Resistor
When control panel is On, short or open starts Entry Delay 2 if no
Trouble Option.
Follows Entry Delay 1 or 2. Follows Exit Delay.
If this Zone Function type is faulted or bypassed at the start of
Exit Delay or during Exit Delay, Exit Time is set to Exit Delay 2.
If this Zone Function type is programmed for Trouble and a
trouble condition occurs when the control panel is armed, an
alarm event is generated.
If a trouble condition occurs when the control panel is disarmed,
a trouble event is generated.
Entry/Exit Delay and Start Entry Delay settings are ignored for
trouble events.
Tamper-Wired,
Zone-Doubled,
No EOL Resistor
When control panel is On, fault starts Entry Delay 2 if no Trouble
Option.
Follows Entry Delay 1 or 2. Follows Exit Delay.
If this Zone Function type is faulted or bypassed at the start of
Exit Delay or during Exit Delay, Exit Time is set to Exit Delay 2.
If this Zone Function type is programmed for Trouble and a
trouble condition occurs when the control panel is armed, an
alarm event is generated.
If a trouble condition occurs when the control panel is disarmed,
a trouble event is generated.
Entry/Exit Delay and Start Entry Delay settings are ignored for
trouble events.
Alarm {8}, Cross Alarm {15}, Unverified
Cross {17}, Bypass {28,29}, Forced Pt
{32}, Swinger Shunt {33}, Unbypass
{35}, Swinger Shunt Restore {173},
Trouble {144}, Trouble Restore {151},
Missing Alarm {87}, Missing Trouble {88},
Restore from Alarm {117}, Restore from
Missing Alarm {175}, Restore from
Missing Trouble {176}
13
Controlled
Follower
Single EOL
Resistor
Tamper-Wired,
Zone-Doubled,
No EOL Resistor
Follows Exit Delay.
Follows, but cannot start Entry Delay.
Instant if first.
If this Zone Function type is programmed for Trouble and a
trouble condition occurs when the control panel is armed, an
alarm event is generated.
If a trouble condition occurs when the control panel is
disarmed, a trouble event is generated.
Entry/Exit Delay and Start Entry Delay settings are ignored for
trouble events.
Alarm {9} reports, Cross Alarm {16},
Unverified Cross {17}, Bypass {28,29},
Forced Pt {32}, Swinger Shunt {33},
Unbypass {35}, Missing Alarm {87},
Swinger Shunt Restore {173}, Trouble
{145}, Trouble Restore {152}, Missing
Trouble {88}, Restore from Alarm {118},
Restore from Missing Alarm {175},
Restore from Missing Trouble {176}