DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 100
Bosch Security Systems | 8/04 | 4998153891C
Reporting Enable, Trouble Response Options, Zone Function ##
Single EOL Resistor Configuration
• Address: See Table 17 on page 88
• Default: See Table 17 on page 88
• Selections: 0 to 15
Enter This Data Digit to Select Options
Reporting Enable, Trouble Response Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Alarm or Trouble Reports
•
Alarm Reports Enabled
• • • • • • • •
Trouble Response on Open
• • • • • • • •
Trouble Response on Short
• • • • • • • •
Alarm Restoral Reports Enabled
• • • • • • • •
Use the option parameter key above if the zone is configured for a single EOL resistor. See Zone Wiring
Configuration on page 89 for more information.
The trouble response for non-24-hour zones and 24-hour burglary Zone Function types occurs only when their
area is disarmed. When armed, any zone fault generates an alarm response. Other 24-hour zone types (Tamper,
Emergency, Panic and Invisible) always have trouble response as programmed.
Fire zone types always have Trouble Response on Open and Alarm Response on Short regardless of
programming.
• Alarm Reports Enabled: If this option is enabled, the system generates Alarm reports.
• Trouble Response on Open: If this option is enabled, an open circuit generates a Trouble response.
• Trouble Response on Short: If this option is enabled, a shorted circuit generates a Trouble response.
• Alarm Restoral Reports Enabled: If this option is enabled, the system generates Alarm Restoral reports.