DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 33
Bosch Security Systems | 8/04 | 4998153891C
4.2.6 Programming Options
Date Format and Enable PIN Trouble
• Address: 0235
• Default: 1
• Selections: 0 to 3
Enter This Data Digit to Select Options
Date Format & Enable PIN Trouble Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
MM/DD/YY Date Display
• •
DD/MM/YY Date Display
• •
Enable Default PIN Trouble
• •
Reserved
Reserved
This parameter controls the display of the date on the keypad and logged on the printer.
This parameter can also enable the System Trouble event that is generated if the default values for the Installer
PIN and User PIN are left unchanged. See Installer PIN, on page 63, and PIN, User #, on page 65, for more
information.
If the default Installer PIN or the default User 1 PIN is changed using RPS remote programming, reset
the control panel at the end of the remote programming session.
Set this parameter to 1 (default) to do the following:
• Use DD/MM/YY date format
• Disable the system trouble message if the Installer PIN and User PIN defaults are not changed
Daylight Saving Time Calendar
• Address: 0236
• Default: 2 (European DST Calendar)
• Selections:
− 0 = No Options selected
− 1 = Australian DST Calendar
− 2 = European DST Calendar
− 3 = United States DST Calendar
This parameter determines the appropriate calendar for daylight saving adjustments.
• Australian DST Calendar: This option moves the clock ahead on the last Sunday in October and moves the
clock back on the last Sunday in March.
• European DST Calendar: This option moves the clock ahead on the last Sunday in March and moves the
clock back on the last Sunday in October.
• United States DST Calendar: This option moves the clock ahead on the first Sunday in April and moves the
clock back on the last Sunday in October.