DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 118
Bosch Security Systems | 8/04 | 4998153891C
Table 26: Output Mode Options (continued)
Mode Mode Type Output
Type
Description
State Output turns off when the condition is active and remains off until [System Reset] is
pressed.
9 Latch,
Reversed
Logic Normal
Event Output turns off when the event occurs and remains off until [System Reset] is
pressed.
State When the condition is active, the output pulses. When the condition is inactive, the
output is on.
10 Pulse,
Reversed
Logic Normal
Event When the event occurs, the output pulses. The output continues pulsing until [System
Reset] is pressed, then turns on.
State When the condition changes from inactive to active, the output turns off. The output
turns on at the end of the One-Shot time. While the output is off, any changes in the
condition are ignored.
11 One-Shot,
Reversed
Logic Normal
Event When the event occurs, the output turns off and remains off for the One-Shot time.
While the output is off, a second event does not affect the output.
State When the condition changes from inactive to active, the output turns off and remains
off for the One-Shot time. If the condition goes inactive and active again, the One-Shot
time is restarted and the output remains off.
12 One-Shot
with Re-
Trigger,
Reversed
Logic Normal
Event When the event occurs, the output turns off and remains off for the One-Shot time. If a
new event occurs, the One-Shot time is restarted and the output remains off.
State When the condition changes from inactive to active, the output turns off and remains
off for the One-Shot time. If the condition goes inactive, the output is turned on early.
13 One-Shot
with Reset,
Reversed
Logic Normal
Event When the event occurs, the output turns off and remains off for the One-Shot time.
[System Reset] turns the output on early.
Base, Output ##
• Address: See Table 24 on page 110
• Default: 0 (Disabled)
• Selections:
− 0 = Disabled
− 1 = 200 ms (on-board outputs only)
− 2 = 1 second
− 3 = 1 minute
− 4 = 1 hour
Multiply the Base with the Multiplier to determine the output’s timing. See Table 27, on page 119, and Table 28, on
page 119.
Multiplier, Output ##
• Address: See Table 24 on page 110
• Default: 0,0 (Disabled)
• Selections: 0,0 to 9,9
Multiply the Base with the Multiplier to determine the output’s timing. See Table 27, on page 119, and Table 28, on
page 119.