DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 77
Bosch Security Systems | 8/04 | 4998153891C
[Q] Button Configuration Options
• Address: 1264
• Default: 0
• Selections: 0 to 1, 3 to 5, 7 to 9, 11 to 13, 15
Enter This Data Digit to Select Options
[Q] Button Configuration Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Options Selected
•
Enable [Q] Button Reporting
•
• • • • • • •
Enable [Q] Button Voice Verification
• • • •
Enable [Q] Button Alarm Output
• • • • • •
Enable [Q] Button Ack Beep
• • • • • •
This parameter configures the [Q] button on the RF3501E 1-Button Pendant (or other device with a [Q] button.
This is a global parameter and affects the programming of all key fobs with [Q] buttons in all areas.
• Enable [Q] Button Reporting: If enabled, this option sends a report to the control panel using the ABC Keys
and Duress Report Routing (see page 73). If this option is disabled, the report is logged into the control panel’s
history only if the report routing specifies events to the log/printer. If Address 1263 is set to “No Alarm
Response,” then no report is sent and no event is placed in the control panel’s history log.
• Enable [Q] Button Voice Verification: If enabled, this option activates the Voice Verification response only
is a report is actually sent. When the report is acknowledged, the voice verification session begins.
• Enable [Q] Button Alarm Output: If enabled, this option activates alarm output types 1|5, 1|6, 1|8, 1|9, 1|10,
and 8|8.
• Enable [Q] Button Ack Beep: If enabled, this option beeps the area keypads after a report is sent. All
keypads in the area beep when the control panel receives the acknowledgement (ack) that the report was
received. The area keypads beep as soon as the [Q] button is pressed if any of the following conditions are
true:
− [Q] button alarm response is set to “No Alarm Response” (see Address 1263)
− [Q] button reporting is disabled
− [Q] button report routing does not send a report