Authority Level Option 9: System Functions 1
Address: 0372
Default: 3
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 9: System Functions 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the following functions by authority level:
View Alarm Memory ([#][4][0])
System Test ([#][4][1])
View System Trouble ([#][4][2])
Remote Program ([#][4][3])
1
Walk Test ([#][4][4])
Reset Sensors ([#][4][7]) [System Reset]
2
View Zone Trouble ([#][4][8])
1
To enable the Remote Program function, see Remote Programming Options on page 35.
2
Enable this parameter for Reset Sensor [#][4][7] for each user that can reset tamper and major trouble conditions
(see Tamper Reset/Arming Options on page 44).