Table 31: Control Panel Events and Reporting Formats (continued)
Event Event as shown in
Control Panel Log
SIA Report Contact ID
Report
Event Description Zone Types
Linked to Event
RPS
Event
Group
Status
Report
136 System Inactive
CD Closing
Delinquent
System was not armed in Inactive
Interval.. System Reset key
sequence ([#][4][7]) or arming
resets this trouble.
12 R
137 Test,OK
RP Automatic
Test
602 Period
Test Report
No system troubles at automatic
test report time.
13
138 Test,Off-Normal
RY Test Off
Normal
608 Period
Test Report,
System Trouble
Present
System trouble present at test time. 13
139 Trbl,Tamper
TT Tamper
Trouble
380 Sensor
Trouble
Trouble condition on Tamper or any
tamper-wired zones.
4-Tamper or any
zone
6
140 Trbl,Emergency
QT Emergency
Trouble
380 Sensor
Trouble
Trouble condition on Emergency
zone type.
5- Emergency 6
141 Trbl,Panic PT Panic Trouble
375 Panic
Zone Trouble
Trouble condition on Panic zone
type.
6- Visible Panic 6
142 Trbl,Invisible
HT Holdup
Trouble
375 Panic
Zone Trouble
Trouble condition on Invisible zone
type.
7-Invisible Panic 6
143 Trbl,24-hr Burg
BT Burglary
Trouble
380 Sensor
Trouble
Trouble condition on Burglary zone
type.
8- Burglary
15 - Door
6
144 Trbl,Cntrl,Dly
BT Burglary
Trouble
380 Sensor
Trouble
Trouble condition on Delay zone
types.
11- E/E Delay 1
12- E/E Delay 2
6
145 Trbl,Cntrl
BT Burglary
Trouble
380 Sensor
Trouble
Trouble condition on Keyswitch,
Follower, and Instant zone types.
10- Keyswitch
13- Follower
14- Instant
6
146 Rstrl,Trbl,Tmpr
TJ Tamper
Trouble Restore
380 Sensor
Trouble
Restoral from Tamper trouble
condition.
4- Tamper or
any zone
8
147 Rstrl,Trbl,Emerg
QJ Emergency
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition on
Emergency zone type.
5- Emergency 8
148 Rstrl,Trbl,Panic
PJ Panic Trouble
Restore
375 Panic
Zone Trouble
Restoral from trouble condition on
Panic zone type.
6- Visible Panic 8
149 Rstrl,Trbl,Invis
HJ Holdup
Trouble Restore
375 Panic
Zone Trouble
Restoral from trouble condition on
Invisible zone type.
7-Invisible Panic 8
150 Rstrl,Trbl,24-hr
BJ Burglary
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition on
Burglary zone type.
8- Burglary
15 - Door
8
151 Rstrl,Trbl,Dly
BJ Burglary
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition on
Delay zone types.
11- E/E Delay 1
12- E/E Delay 2
8
152 Rstrl,Trbl,Cntrl
BJ Burglary
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition on
Keyswitch, Follower, and Instant
zone types.
10- Keyswitch
13- Follower
14- Instant
8
153 User Code Area Set
JY User Code
Added
User Code ‘added’ by assigning
area.
16 R
154 User Code Change
JV User Code
Changed
User Code changed. 16 R
155 User Code Delete
JX User Code
Deleted
User Code deleted. 16 R
156 User Code Tamper
JA User Code
Tamper
461 Wrong
Code Entry
Invalid User Codes entered at
keypad exceeded User Tamper
Retry Count. See page 62.
16 R
157 User Level Set JZ User Level Set User Level set. 16 R