Tamper Reset/Arming Options
• Address: 3408
• Default: 3
• Selections: 0 to 3
Enter This Data Digit to Select Options
Tamper Reset/Arming Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Tamper Reset/Arming Options
•
Allow User Reset of Tampers/Troubles
• •
Allow Force Arming of Tampers/Troubles
• •
Reserved
Reserved
This parameter enables user reset of a tamper or trouble condition and force arming of the control panel when a
tamper or trouble condition exists.
• Allow User Reset of Tampers/Troubles: If enabled, this option allows a user with the appropriate authority
level to reset tamper and major trouble conditions. Enable Authority Level Option 9: System Functions 1 (page 57)
and Authority Level Option 10: System Functions 2 (page 58) for each user who can reset tamper and trouble
conditions.
The following conditions are treated as major trouble conditions:
− 24-hour zone missing (DX2010 Data Bus device missing)
− Controlled zone missing (DX2010 Data Bus device missing)
− Low or missing system battery
− Telephone line fail (if programmed for user reset)
− Alternate communication path fault (if programmed for user reset)
− 24-hour zone trouble (zone programmed for trouble, not alarm)
− Controlled zone trouble (zone programmed for trouble, not alarm)
• Allow Force Arming of Tampers/Troubles: If enabled, this option allows a user with the appropriate
authority level to force arm the control panel when a tamper or major trouble condition exists. Enable
Authority Level Option 7: Force Arm/Bypass (page 56) for each user who can force arm the system when a tamper
or trouble condition occurs. If the tamper or trouble is zone-related, the zone function configuration must
have the "Can Be Bypassed or Force Armed" options enabled (see Options 2, Zone Function ## on page 99).