DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 14
Bosch Security Systems | 8/04 | 4998153891C
4.2.3 Phone, Auto-Forward, and RPS Configuration
Integral Voice Verification Module
Address: 0065
Default: 0
Selections:
0 = Disable Voice Verification
1 to 15 = Enable the Voice Verification Module and identify which output is the Voice Request output in
Area 1
This parameter enables the voice verification module. Program one of the first 15 outputs as Output Function
Type 2|10 “Voice Request.” Enter that output number (1 to 15) in this parameter. See Function, Output ## on page
112 for more information.
Set this address to 0 if the integral voice verification module is not installed.
Phone Line Options
Address: 0131
Default: 0
Selections: 0 to 3, 8 to 11
Enter This Data Digit to Select Options
Phone Line Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Phone Line Options
Do Not Wait for Dial Tone
• •
• •
“R” Function/Three-way Calling
Reserved
Phone Line Fault Requires Reset
• • • •
This parameter consists of three options for the physical phone line.
Do Not Wait for Dial Tone: If this option is enabled, the control panel waits three sec after going off-hook
and then starts dialing. If this option is disabled, the control panel waits up to seven sec for a dial tone. The
control panel dials when it detects the dial tone.
“R” Function/Three-way Calling: If this option is enabled, the control panel’s “R” function/three-way
calling feature is enabled. The phone company must enable this option on the control panel’s telephone line.
Phone Line Fault Requires Reset: If this option is enabled and a phone line fault occurs, the trouble
condition (keypad trouble message and/or tone) continues until the [System Reset] key is pressed (fix the
phone line fault first). If this option is not disabled and a phone line fault occurs, the trouble condition clears
automatically when the phone line fault is corrected. This option also applies to the Alternate Communication
Path Fault Control Input (see Options 1 for Zone Function Type 3 (24-hr Control Input) on page 97).