Bosch DS7200V2-EXP Guide de l'utilisateur Page 53

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 156
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 52
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 53
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 2: Perimeter Only Arming
Address: 0365
Default: 15
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 2: Perimeter Only Arming 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required (Quick Arm)
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the following functions by authority level:
[#][2]: Perimeter Only with Entry Delay
[#][2]: Perimeter Only with Entry Delay, No Exit Tone*
[#][2]: Perimeter Only with No Entry Delay
[Perimeter Only] Key: Perimeter Only with Entry Delay
[Perimeter Only] Key: Perimeter Only with Entry Delay, No Exit Tone*
[Perimeter Only] Key: Perimeter Only with No Entry Delay
If a PIN is required and not entered, the system asks for one after the function is entered.
Zones must be configured for Perimeter Only arming. See Options 1, Zone Function ## on page 95.
* Exit Time is doubled (up to 254 sec) when arming the system Perimeter Only with Delay, Silent (no Exit Tone).
To enable the “Quick Arm” feature, set Authority Level Option 2 to 0. A user PIN entry is not required for
Perimeter Only arming.
Authority Level Option 3: Partial On Arming
Address: 0366
Default: 15
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 3: Partial On Arming 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required (Quick Arm)
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the following functions by authority level:
[#][3]: Partial On Arming with Entry Delay
[#][3]: Partial On Arming with Entry Delay, No Exit Tone*
[#][3]: Partial On Arming with No Entry Delay
If a PIN is required and not entered, the system asks for one after the function is entered.
* Exit Time is doubled (up to 254 sec) when Partial On Arming the system with Entry Delay, Silent (no Exit
Tone).
To enable the “Quick Arm” feature, set Authority Level Option 3 to 0. A user PIN entry is not required for Partial
On arming.
Vue de la page 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 155 156

Commentaires sur ces manuels

Pas de commentaire