Bosch DS7200V2-EXP Guide de l'utilisateur Page 28

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 156
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 27
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 28
Bosch Security Systems | 8/04 | 4998153891C
System Alarm Reports/Output Options
Address: 3407
Default: 7
Selections: 0 to 7
Enter This Data Digit to Select Options
System Alarm Reports/Output Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No System Tamper Alarm Reports, No Output
Send System Tamper Alarm Reports
• •
Send System Tamper Alarm Restoral Reports
Enable System Tamper Alarm Output
Reserved
This parameter determines whether tamper alarm and alarm restoral reports are sent, and if the alarm output
operates on a tamper alarm. This parameter only applies to non-zone tampers.
Send System Tamper Alarm Reports: If enabled, this option sends an alarm report, such as Data Bus
Device Tamper {189} alarm, to the ARC when a non-zone related tamper alarm is generated. Other non-zone
tamper alarms include Data Bus Missing Alarm {187}, Data Bus Trouble Alarm {191}, and Siren Missing
Alarm {193}.
Send System Tamper Alarm Restoral Reports: If enabled, this option sends an alarm restoral report, such
as Data Bus Device Tamper {190} restoral, to the ARC when a non-zone related tamper condition is restored.
Other non-zone tamper alarm restorals include Data Bus Missing Alarm Restoral {188}, Data Bus Trouble
Alarm Restoral {192}, and Siren Missing Alarm Restoral {194}.
Enable System Tamper Alarm Output: If enabled, this option activates the alarm output when a non-zone
related tamper alarm, such as Data Bus Device Tamper alarm, is generated. Other non-zone tamper alarms
include Data Bus Missing {187}, Data Bus Trouble Alarm {191}, and Siren Missing Alarm {193}.
4.2.5 Tests
System Test Configuration Options
Address: 0244
Default: 5
Selections: 0 to 15
Enter This Data Digit to Select Options
System Test Configuration Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
System Test Disabled
Test Bell
• • • • • • • •
Test Strobe
Test Battery
• • • • • • • •
Send Test Report
• • • • • • • •
This is a global (affects all areas) option.
When the user enters the System Test key sequence ([#][4][1]) at the keypad, the system performs a self-test that
includes the options selected at this parameter. The configuration applies to all areas.
Test Bell: If enabled, this option makes a “bell test” part of the system test. The control panel activates the
Bell Time (1|5) and Alarm Output (1|8, 1|9, 1|10, 1|11, 1|12, and 8|8) functions for three sec. See Output
Parameters on page 107 for a complete description of output functions.
Test Strobe: If enabled, this option makes a “strobe test” part of the system test. The control panel activates
the Strobe Output function (1|6) and waits for the user to press [*] to end the test.
Vue de la page 27