DACM Global Options
Address: 3562
Default: 0
Selections: 0, 1, 3-5, 7
Enter This Data Digit to Select Options
DACM Global Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No DACM Global Options Selected
Enable Arming Confirmation
• •
Any User Confirms Arming
Use Tamper-Wired Processing
Reserved
This is a global parameter that affects all DACMs connected to the control panel.
Enable Arming Confirmation: If this option is enabled, verifying a user at the DACM reader during Exit
Delay cancels the remaining Exit Delay time and arms the control panel immediately. Only the user who
started the arming process can confirm arming. If this option is disabled, verifying a user at the DACM reader
during Exit Delay cancels the arming process (the system does not arm).
Any User Confirms Arming: If this option is enabled, any user can confirm system arming. If this option is
disabled, only the user who started the arming process can confirm arming. This option only applies when
“Enable Arming Confirmation” is selected.
Use Tamper-Wired Processing: If this option is enabled, an open door reports as faulted (the zone assigned
to the DACM functions as a tamper-wired zone). If this option is disabled, an open door reports as shorted
(the zone assigned to the DACM functions as a single EOL zone).