DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 55
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 6: Send Open/Close Reports
• Address: 0369
• Default: 0
• Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 6: Send Open/Close
Reports
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Send Open/Close Reports for Authority Levels 1-4
•
Authority Level 1 does not send Open/Close
Reports
• • • • • • • •
Authority Level 2 does not send Open/Close
Reports
• • • • • • • •
Authority Level 3 does not send Open/Close
Reports
• • • • • • • •
Authority Level 4 does not send Open/Close
Reports
• • • • • • • •
No Open/Close reports are sent for the authority level(s) selected at this parameter.
For example, if Open/Close reports are enabled for an area and Open/Close reports are disabled for Authority
Level 1 in this parameter, the control panel sends Open/Close reports for users assigned to Authority Levels 2, 3
and 4. It does not send Open/Close reports for users assigned to Authority Level 1, even though Open/Close
reports are enabled for the area.
See the following parameters to properly enable/disable Open/Close Reporting:
• Routing Destinations on page 9
• Global Reporting Options on page 19
• Open/Close Reporting Options on page 39
• Area # Opening {89-96}/Closing {42-67} Reporting Options on page 49
If you quick arm the system, this option is ignored and closing reports are sent with user ID 255.
Opening reports are not sent.