DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 45
Bosch Security Systems | 8/04 | 4998153891C
Contact Set/Exit Delay Cancel Zone Options
• Address: 3409
• Default: 0
• Selections: 0 to 15
Enter This Data Digit to Select Options
Contact Set/Exit Delay Cancel Zone Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Contact Set Arming
•
Enable Contact Set in Area 1
• • • • • • • •
Enable Contact Set in Area 2
• • • • • • • •
Enable Contact Set in Area 3 (DS7240V2 only)
• • • • • • • •
Enable Contact Set in Area 4 (DS7240V2 only)
• • • • • • • •
This parameter selects which areas arm when an Entry/Exit Delay zone restores during Exit Delay and all zones
are normal. Each area can be individually selected to arm on contact (Exit Delay cancel zone).
Contact Set only applies when turning the system All On. If the system is turned Perimeter Only or Partial On,
the control panel only arms at the end of Exit Delay. When any Entry/Exit Delay zone (either Type 1 or Type 2)
goes from its alarm (off-normal) condition to normal, and all other zones in the area are normal or bypassed, Exit
Delay is terminated and the control panel is armed.
If a zone is faulted when the Exit zone restores, the restoral is ignored. Entry/Exit zones may or may not be
bypassed. If all Entry/Exit zones are bypassed and the Exit Delay time is set to 0 (disabled), the control panel
cannot be armed All On.
Exit Terminator Zone Options
• Address: 3410
• Default: 0
• Selections: 0 to 15
Enter This Data Digit to Select Options
Exit Terminator Zone Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Terminator Arming
•
Enable Exit Terminator Arming in Area 1
• • • • • • • •
Enable Exit Terminator Arming in Area 2
• • • • • • • •
Enable Exit Terminator Arming in Area 3
(DS7240V2 only)
• • • • • • • •
Enable Exit Terminator Arming in Area 4
(DS7240V2 only)
• • • • • • • •
This parameter selects which areas arm when an exit terminator button is assigned to that area. Each area can be
individually selected to arm on the activation of an exit terminator button.
Each button only arms the area to which its zone is assigned.
When Exit Delay is active, all zones are normal, and the exit terminator button is pressed, the control panel arms
immediately (see Location ##, Zone Function on page 84 for more information). The exit terminator button applies
only to All On arming, and is assigned a specific zone function. If the control panel is turned Perimeter Only or
Partial On, it only arms at the end of Exit Delay. If a zone is faulted when the button is pressed, the button is
ignored.