DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 56
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 7: Force Arm/Bypass
• Address: 0370
• Default: 7
• Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 7: Force Arm/Bypass 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
•
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
• • • • • • • •
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the following functions by authority level:
• Force Arm
• [#][0]: Selective Bypass
• [Bypass] Key
Zones must be configured for Bypass/Force Arm operation. See Options 2, Zone Function ## on page 99.
Authority Level Option 8: All Areas On/Off
• Address: 0371
• Default: 3
• Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 8: All Areas On/Off 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
•
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
• • • • • • • •
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the following functions by authority level:
• [#][8][0]: All On with Delay, All Areas
• [#][8][1]: Off, All Areas
Both of these functions must be enabled at the system level first. See Arming Options 2 on page 38.
For [#][8][0] to work as described, the authority level assigned to Authority Level Option 8 must match the
authority level assigned to Authority Level Option 1 (All On Arming).
For [#][8][1] to work as described, the authority level assigned to Authority Level Option 8 must match the
authority level assigned to Authority Level Option 4 (Disarming the System).