DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 84
Bosch Security Systems | 8/04 | 4998153891C
Location ##, Zone Function
Address: See Table 13 on page 80
Default: See Table 13 on page 80
Selections: 0 to 15 (see Table 15 for Default Zone Function Types)
The zone function determines how the system responds to changes on the sensor loop assigned to the location.
There are two general categories of zones: 24-hour and Controlled.
24-hour Zone: 24-hour zones are always on and cannot be turned off by the user. Faults on 24-hour zones
prevent turning the system on.
Controlled Zone: Controlled zones are turned on and off when the user turns the system on (armed) and off
(disarmed).
See Table 15 for Zone Function selections.
Table 15: Default Zone Function Type Selections
Zone Function
Selection
Default Zone Function Type
0 Disabled
1 24-hour Fire, Normally Open Contact
2 24-hour Fire with Alarm Verification, Normally Open Contact
3 24-hour Voice Active Control Input, Normally Open Contact with EOL Resistor
4 24-hour Tamper (no EOL resistor)
5 24-hour Emergency (no alarm output)
6 24-hour Visible Panic (no alarm output)
7 24-hour Invisible Panic (no alarm output)
8 24-hour Burglary
24-Hour Zones
9 Chime Mode only
10 Controlled Keyswitch, Momentary, All On, Off from Any Armed State
11 Controlled Entry/Exit Delay 1
12 Controlled Entry/Exit Delay 2
13 Controlled Follower
14 Controlled Instant
15 Controlled Instant (Perimeter)
Controlled
Zones