DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 120
Bosch Security Systems | 8/04 | 4998153891C
4.7 Sked Parameters
Skeds are programmable events that occur at a specified time of day and day of the week.
Users can extend Auto On, Auto Perimeter Only On and Auto Partial On time by one h using the Extend Auto
On Time function ([#][5][1]). When [#][5][1] is entered, the control panel sends an Auto On Extended {21} report.
Users can also change Skeds using the Change Skeds function ([#][5][2]). A Sked must first be entered before the
Change Skeds function is used.
The following sections and parameters detail the programming of each of the eight Skeds. The parameters in
Output Parameters on page 107 determine the characteristics of the output activation that occurs at the Sked time.
See Table 29 for Sked configuration parameter addresses.
The default setting for all Sked parameters is 0 (zero).
Table 29: Sked Configuration Parameters
Time Sked Type Assign
(Area or
Output)
(H _ _ _) (_H _ _) (_ _ M _) (_ _ _ M)
Days 1
Option
Days 2
Option
1 Addr 1184 Addr 1185 Addr 1186 Addr 1187 Addr 1188 Addr 1189 Addr 1190 Addr 1191
2 Addr 1192 Addr 1193 Addr 1194 Addr 1195 Addr 1196 Addr 1197 Addr 1198 Addr 1199
3 Addr 1200 Addr 1201 Addr 1202 Addr 1203 Addr 1204 Addr 1205 Addr 1206 Addr 1207
4 Addr 1208 Addr 1209 Addr 1210 Addr 1211 Addr 1212 Addr 1213 Addr 1214 Addr 1215
5 Addr 1216 Addr 1217 Addr 1218 Addr 1219 Addr 1220 Addr 1221 Addr 1222 Addr 1223
6 Addr 1224 Addr 1225 Addr 1226 Addr 1227 Addr 1228 Addr 1229 Addr 1230 Addr 1231
7 Addr 1232 Addr 1233 Addr 1234 Addr 1235 Addr 1236 Addr 1237 Addr 1238 Addr 1239
8 Addr 1240 Addr 1241 Addr 1242 Addr 1243 Addr 1244 Addr 1245 Addr 1246 Addr 1247
Type, Sked #
Address: See Table 29
Default: 0 (No type assigned)
Selections:
0 = No Type Assigned (Sked disabled)
1 = Auto All On
2 = Auto Perimeter Only On
3 = Auto Partial On
4 = Auto Off
5 = Output On (DS7240V2: Outputs 1 to 15; DS7220V2: Outputs 1 to 12)
6 = Output Off (DS7240V2: Outputs 1 to 15; DS7220V2: Outputs 1 to 12)
The Sked Types "Output Function On" and "Output Function Off" override any output function at Sked time
(except for Alarm Output Functions 1|8 to 1|12). For example, an output function that turns a light on is
overridden by a Sked that turns the same light on.