Bosch DS7200V2-EXP Guide de l'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 156
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 61
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 15: View Log
Address: 0378
Default: 3
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 15: View Log 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the View Log function ([#][8][5]) by authority level.
4.4.2 PIN Configuration/Installer PIN
A Personal Identification Number (PIN) is a unique number issued at the time of installation of each system. This
PIN is required to operate the system (arm/disarm, test system, initiate functions, etc.). The PIN is not the same as
the account number.
PIN Length
Address: 0379
Default: 4 (4 digits long)
Selections: 3 to 7 (3 digits min; 7 digits max)
This parameter determines the number of digits in a PIN. All user PINs and the Installer PIN follow this length.
If the PIN length is shortened after PINs are entered, duplicate PINs could be created (for example,
PINs 1235 and 1238 would both become 123).
Vue de la page 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 155 156

Commentaires sur ces manuels

Pas de commentaire