
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 134
Bosch Security Systems | 8/04 | 4998153891C
Alternate Communication Heartbeat Period
• Address:
− IP Address 1, Destination 1: 3510 to 3513
− IP Address 2, Destination 1: 3518 to 3521
− IP Address 1, Destination 2: 3526 to 3529
− IP Address 2, Destination 2: 3534 to 3537
• Default: 0, 0, 7, 5
• Selections: 0 to 1275 sec
Use this parameter to set the rate that the DX4020 polls the ARC.
This parameter uses four addresses for each routing destination. In the first address, enter the 1000’s value (this
value is multiplied by 1000). In the second address, enter the 100’s value (this value is multiplied by 100). In the
third address, enter the 10’s value (this value is multiplied by 10). In the fourth address, enter the 1’s value (the
1000’s, 100’s, and 10’s values are added to the 1’s value).
The following example shows how to get an alternate communication wait time of 5555 sec for IP Address 1,
Destination 1:
[5 x 1000] + [5 x 100] + [5 x 10] + 5 = 5555 sec
If the entries equal 0 sec, this parameter is disabled.
If the entries equal 1 to 4 sec, this parameter is automatically set to 5 sec.
If the entries exceed 1275 sec, this parameter is automatically set to 1275 sec.
Alternate Communication Heartbeat Retries
• Address: 3539 to 3540
• Default: 0, 2
• Selections: 0 to 99 retries
Use this parameter to define how many times the DX4020 tries to send reports to the ARC before declaring a
communication failure.
This parameter uses two addresses. Address 3539 sets the 10’s value, and Address 3540 sets the 1’s value. For
example, if you want the DX4020 to make 10 communication attempts before declaring a communication failure,
enter “1” in Address 3539 and “0” in Address 3540.
Address 3510 Entry
Address 3511 Entry
Address 3512 Entry
Address 3513 Entry
Commentaires sur ces manuels