DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 89
Bosch Security Systems | 8/04 | 4998153891C
Zone Wiring Configuration
The operation and configuration of the zone function depends on the method of zone wiring. A zone is a “Single
EOL resistor” zone if the zone is supervised with one end of line resistor. Table 18 defines configuration options
for single EOL resistor zones.
Table 18: Single EOL Resistor Zone Configuration Options
Device Selection as
shown in Table 13
Address for Zone Wiring
Configuration Options
Configuration
Options
1 1026 1, 2, 3
2 1257 to 1261 4 to 11
4 or 5 1249 4 to 7
For On-board zones, device is 1. See On-board Location EOL Resistor Value on page 103.
For Wired-Expander zones, device is 2. See DX2010 Configuration Options on page 127.
For RF zones, Device is 4 or 5. See RF Receiver Configuration on page 123.
Tamper-wired zones, Zone-doubled zones, or No EOL resistor zones function differently. These non-single EOL
resistor zones are defined by the configuration options shown in Table 19.
Table 19: Tamper-wired, Zone Doubled, and No EOL Resistor
Zone Configuration Options
Device Selection as
shown in Table 13
Address for Zone Wiring
Configuration Options
Configuration
Options
1 1026 0, 4, 5, 6
2 1257 to 1261 0 to 3
3 N/A Always
4 or 5 1249 0 to 3