DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 59
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 11: Move to Area
Address: 0374
Default: 3
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 11: Move to Area 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts Move to Area function ([#][5][0]) by authority level.
The Move to Area function allows the user to control multiple areas from one keypad when the system is split into
more than one area. See the DS7200V2 User’s Guide (P/N: 4998153894) for more information.
Authority Level Option 12: Extend Auto-On Time
Address: 0375
Default: 3
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 12: Extend Auto-On Time 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the Extend Auto On Time function ([#][5][1]) by authority level.
The Extend Auto-On Time function delays the auto-on time by one hour if entered during the Auto-On Alert
Time. See the DS7200V2 User’s Guide (P/N: 4998153894) and Auto On Alert Time on page 26 for more information.