DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 76
Bosch Security Systems | 8/04 | 4998153891C
RF Keypad # Area
• Address:
− RF Keypad 1: 2931
− RF Keypad 2: 2933
− RF Keypad 3: 2935
− RF Keypad 4: 2937
• Default: 0 (Disabled)
• Selections:
− 0 = Disabled (No Area Assigned)
− 1 = Assign RF Keypad to Area 1
− 2 = Assign RF Keypad to Area 2
− 3 = Assign RF Keypad to Area 3 (DS7240V2 only)
− 4 = Assign RF Keypad to Area 4 (DS7240V2 only)
To enable an RF keypad, assign it to an area. To disable an RF keypad, enter a 0 at this parameter.
4.4.7 Q Button Configuration
[Q] Button Alarm Response Options
• Address: 1263
• Default: 0
• Selections:
− 0 = No Alarm Response
− 1 = Panic Alarm Response
− 2 = Emergency Alarm Response
− 3 = Duress Alarm Response
This parameter assigns an alarm response to the [Q] button on the RF3501E 1-Button Pendant (or other device
with a [Q] button). This is a global parameter and affects the programming of all key fobs with [Q] buttons in all
areas.
• No Alarm Response: No alarm outputs are activated and no reports are sent. The [Q] button can be used to
control an output.
• Panic Alarm Response: If Alarm Output is enabled, the control panel sends a Panic {5} report and sounds
the alarm outputs. If Alarm Output is disabled, the control panel only sends an Invisible Panic {6} report. No
keypad tones or displays are generated. This option activates output function type 8|15.
• Emergency Alarm Response: This option displays “User Alarm” at the text keypads. The [Q] button sends
an Emergency Alarm {4} report, and the Burglary Alarm outputs are activated (optional). This option activates
output function type 8|15.
• Duress Alarm Response: This option sends a Duress {74} report. If configured, the text keypads display
“User Alarm” and the alarm outputs activate. This option makes the [Q] button function the same as Panic on
the keyfob. This option activates output function types 2|1, 2|2, and 8|15.