DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 84
Bosch Security Systems | 1/05| 4998154963B
Data Digit 2 assigns the status event to be followed. When this event occurs, all outputs using this output function
activate. See Table 126 for Data Digit 2 options.
Table 123: Output Function to Follow Status
Events System Wide, Data Digit 2
Select Option Selections for
Data Digit 2
AC Power Failure 1
Low Battery 2
Communication Failure 3
System Fault
1
4
Keypad Supervision Fault 5
Multiplex Bus Fault 6
Radio Receiver Fault 7
Aux Power Fault 8
Fire Trouble 9
Supervisory *0
Zone Trouble *1
Duress PIN *2
1
System Faults include:
RAM Fault Serial Transmit Fault
ROM Fault Serial Receive Fault
Bell/Line Monitor Fault Aux. Relay Fault
Line 1 Fault Alternate Communications Fault
Line 2 Fault RF Receiver Tamper
Bell Fault RF Receiver Jammed
Aux. Power Fault RF Receiver Trouble
Octal Relay Fault Printer Off-Line
Serial Module Fault
For example, use the following steps to program Output Function 3 to follow Low Battery status events.
1. Enter “*2” (see Table 116) in Data Digit 1 of Program Address 2778 (see Table 125).
This option programs the output function to follow status events system-wide.
2. Enter “2” (see Table 126) in Data Digit 2 of Program Address 2778.
This option assigns the output function to follow Low Battery status events. When a low battery status event
occurs, all outputs using this output function activate.
Follow a Single Zone
Data Digit 1 Option *3 programs an output function to follow one zone in an input/output cross matrix. This
option requires the use of two program addresses:
Program Address 1: Enter the output function option in Data Digit 1 (see Table 124); enter the zone/control
panel state option in Data Digit 2 (see Table 125).
Program Address 2: Enter the zone number in Data Digits 1 and 2 using hex values (see Table 113).
See Table 116 for output function options. See Table 124 for output function numbers/program addresses.