DS7400XiV4-EXP | Reference Guide | 7. Reference Materials EN | 117
Bosch Security Systems | 1/05| 4998154963B
All other keypads should be connected to the
keypad bus and may be placed as needed (within
the noted wiring limitations in the installation
manual).
One keypad must be assigned as address 1.
7.2.12 Open/Close Report Control Programming
Open and Close Reports: If programmed, these
reports are sent when the system is armed or disarmed.
They may be sent independently for the opening and
closing of each area, or the first area to open and the
last area to close may send the reports.
Send Trouble at Close for Bypassed Zones: If
programmed, a trouble report will be sent for each zone
bypassed when the system is armed.
Alternate between both Phone Numbers: If
programmed, open and close reports will be sent to
phone number one first. If phone number one does not
pick-up, the control panel will alternate to phone
number two. If phone number two does not pick-up,
the control panel will alternate back to phone number
one. It will alternate between both phone numbers until
successful.
7.2.13 Report Programming
Reports: For pulse formats, reports are programmed by
entering data in the reporting and extended digits. The
report will send the data programmed for each event.
For SIA and Contact ID, the report formats are fixed
and may be activated by placing a 1 in the reporting
digit.
To disable a report, enter a 0 in the reporting digit.
To send the Man No. along with Open and Close
reports, program an “F” (enter [*][5] at the keypad)
in the extended digit.
Keypad Fire Alarm: This report is sent when a fire
alarm has been activated by the “A” emergency key.
Keypad Fire Restoral: This report is sent when a
keypad fire alarm has been restored using the [System
Reset] command.
Keypad Emergency Alarm: This report is sent when
an emergency alarm has been activated using the “B”
emergency key.
Keypad Panic: This report is sent when an emergency
alarm has been activated using the “C” emergency key.
Keypad Tamper: For keypads fitted with a wall
tamper switch, this report is sent when the keypad is
removed from the wall.
Keypad Tamper Restoral: For keypads fitted with a
wall tamper switch, this report is sent when the keypad
is properly replaced on the wall after experiencing a
tamper condition.
Zone Function Alarm: An alarm report is sent when
a zone alarm occurs. Alarm reports are enabled by
zone function. Program this report for any zone
functions you wish to send an alarm report about. For
local zones (no reports), do not program an alarm
report. The zone number will automatically be sent for
this report in SIA or Contact ID format.
Zone Function Restoral: This report is sent when the
zone alarm and trouble conditions are cleared. The
zone number will automatically be sent for this report
in SIA or Contact ID format.
Zone Function Trouble: This report is sent when a
zone trouble condition occurs. This can be an open
circuit, if the zone is programmed for “trouble on
open”, a multiplex tamper switch being activated, or a
multiplex zone not communicating with the control
panel. The zone number will automatically be sent for
this report in SIA or Contact ID format.
Zone Function Bypass: This report is sent when a
zone is bypassed. (Note: Fire zones can never be
bypassed.) Zone bypass reports for non-24 hour zones
are sent with the closing report. Bypass reports for 24
hour zones are sent when the zone is bypassed. If a
zone is force armed, the bypass report is sent with the
partial close report. If a 24 hour or non-24 hour zone
is custom armed, the bypass report is sent with the
partial close report.
Zone Function Bypass Restoral: This report is sent
when the zone bypass is cleared. For non-24-hour
zones the bypass restoral is sent with the open report.
Bypass restoral reports for 24 hour zones are sent
when the zone is manually restored. The bypass
restoral report for a zone that was force armed is sent
when the zone is restored. If a 24 hour or non-24 hour
zone was custom armed, the bypass restoral is sent
with the open report.
Open: This report is sent when the system has been
disarmed. In SIA or Contact ID formats, the user
number for the person who disarmed the system will
be sent with this report. To send the user number
along with an Open report in other formats, program
the extended digit of the report as *5. In Contact ID
format, the area number will also be sent along with
this report. The Open report will only be sent if a
Close report was sent previously.