Bosch DS7400XiV4-EXP Spécifications Page 114

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 144
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 113
DS7400XiV4-EXP | Reference Guide | 7. Reference Materials EN | 114
Bosch Security Systems | 1/05| 4998154963B
Ground Start: This is an output programmed to
activate for 3 seconds when the phone line is seized. It
is intended for use with ground start phone systems that
require a momentary short to ground to obtain a dial
tone.
Connect a separate 12 VDC, DPDT relay.
Connect both relay contact commons to ground,
and connect the Normally Open of each contact to
terminal positions 13 and 16 (one to terminal 13,
the other to 16) of the DS7400Xi.
This output follows all areas regardless of how data
digit 2 of the output programming address is
programmed.
Not intended for UL Listed systems. Not for use
with phone line monitors.
System Status (ready to arm): This is an output
programmed to follow the Status LED of the keypad.
It will activate when the system is ready to arm
with no zones violated.
Zone Alarm: This is an output programmed to activate
when a zone is in an alarm condition.
It will remain activated until the system is disarmed
or the bell cut-off time expires.
This output is intended to activate alarm bells and
sirens.
This will not activate from Silent or Invisible Zones.
Zone Alarm Delayed by 20 sec.: This is an output
programmed to wait 20 seconds after a zone enters an
alarm condition to activate.
It will remain activated until the system is disarmed
or the bell cut-off time expires.
This output is intended to activate alarm bells and
sirens, but provides a delay to allow the user to
silence the system before it activates.
Output Functions: Output Functions can be
programmed to follow system events or to follow one or
two specific zones in a “cross-matrix” fashion (see
Input/Output Cross-Matrixing).
These Output Functions can be programmed to
control Octal Relay outputs or Multiplex Bus
outputs.
Output Functions are programmed in addresses
2772 to 2843.
Input/Output Cross Matrixing: Input/Output Cross
Matrixing allows Output Functions to follow the status
of specific input zones (zones 1 through 248 only).
Outputs can be programmed to follow any
combination of one or two zones, open or closed,
with the system armed or disarmed.
If programmed to latch, the output will latch until
a valid PIN is entered at the keypad.
Keypad Sounder Output: This is an output
programmed to follow the keypad sounder.
It activates during the entry pre-alert and during
any day monitor alarm. It does not follow
momentary keypad beeps such as keystrokes,
chimes, and so on.
Access Output: This is an output programmed to
activate for 10 seconds when an access control PIN is
entered at the keypad.
Panic/Duress Output: All outputs, including the three
on-board outputs, the Octal Relays, and the Output
Functions, support a Panic/Duress function. This
output will follow Duress activations, Keypad
Emergency Keys B and C, and Invisible and Silent
Zone alarms. It will only be reset by a user
acknowledgement and will not reset after the burglary
bell time-out occurs. Duress activations will latch until
acknowledged by a user.
Multiplex Bus Outputs: The DS7400Xi supports up
to 60 DS7465i Input/Output Modules.
These modules are connected to the multiplex bus
and provide one input loop and one Form "C"
output relay.
The input loop operates the same as all other
multiplex inputs.
The output loop can be programmed to follow
Output Functions.
Multiplex Bus outputs can be bypassed using the
bypass function. If an output zone is bypassed
while it is ON, it will turn OFF. The bypass will
not be removed when the system is armed and
then disarmed; it must be cancelled by entering
the bypass command again or by canceling all
bypasses.
DS7465i Module outputs will not pulse,
even if programmed to do so.
Vue de la page 113