5.9.30 Phone Number General Control Programming
See Section 7.2.14 Phone Number General Control Programming for Phone Number General Control glossary
definitions.
• Address: 3155
• Data Digit:
• Data Digit 1: ____ (see Table 94; default = 2)
• Data Digit 2: ____ (see Table 95; default = 0)
• Selections: 0 to 9, *0 to *5 (hexadecimal values that display as A through F at the keypads)
Table 94: Address 3155, Data Digit 1)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1
Enable remote programmer call-back
•
•
•
•
•
•
Dial pulse on all phone numbers
• •
• •
Dial tone on all phone numbers
1
• •
• •
Dial tone, switch to pulse if required
• •
• •
Try DS7416i first
2
• • • • • •
Table 95: Address 3155, Data Digit 2)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Dialer delay of 15 seconds on non-24-hour burglar
alarms only
3
•
•
•
•
•
•
•
•
Dialer delay of 15 seconds on 24-hour burglar and fire
alarms only
3
• •
• •
• •
• •
Send alarms using either DS7416i or digital
4
• • • •
• • • •
Send alarms using both DS7416i and digital
2, 4
• • • •
• • • •
Use 110 baud communication for RPS
• • • •
• • • •
Use 300 baud communication for RPS
• • • •
• • • •
1
Required on PBX systems.
2
If this option is selected, see Section 5.9.28 Phone/DS7416i Routing Control (Program Addresses 3153 and 3154).
3
These selections can only be used with systems that have only one area.
4
Only applicable when using the DS7416i option.