DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 81
Bosch Security Systems | 1/05| 4998154963B
5.9.37 Output Function Programming
Output function programming allows you to have any output follow status events by area or system-wide, or
follow zone outputs in an Input/Output Cross Matrix. See Section 7.2.4 Output Programming for Output Function
Programming glossary definitions. See Table 126 to determine which program addresses make up each output
function.
See the DX7400XiV4 Wireless Reference Guide (P/N: 4998154790) for additional information.
Table 116: Program Addresses 2772 to 2843, Data Digit 1
Selections
Select Option Value For Digit 2, Refer
To:
Latch ON after Zone Alarm 0 Table 118
ON during Entry Pre-Alert 1 Table 118
ON when system is armed 3 Table 119
Zone Alarm 6 Table 118
Zone Alarm delayed by 20 sec 7 Table 118
Keypad Sounder output 8 Table 118
Access output (10 sec pulse) 9 Table 118
Keyfob/RF Keypad output *0 Table 121
Panic/Duress output *1 Table 118
Follow System Status Event *2 Table 123
Follow a single zone *3 Table 124
Follow two zones, when EITHER zone
changes state
*4 Table 127
Follow two zones, when BOTH zones
change state
*5 Table 127
Follow Status Events for Individual Areas (Partitions)
Data Digit 1 Options 0-9 and *1 program an output function to follow status events for individual areas.
See Table 116 for output function options. See Table 117 for output function numbers/program addresses.
Table 117: Output Functions/Program Address 1
Output
Function
1
Program
Address 1
Output
Function
1
Program
Address 1
1 2772 13 2808
2 2775 14 2811
3 2778 15 2814
4 2781 16 2817
5 2784 17 2820
6 2787 18 2823
7 2790 19 2826
8 2793 20 2829
9 2796 21 2832
10 2799 22 2835
11 2802 23 2838
12 2805 24 2841
1
See Section 5.9.38 Output Function Partition Assignment for information on assigning output functions to areas.