Table 138: General System Troubleshooting (continued)
Symptom Probable Cause Possible Solutions
#87 display = Communicator Err
#89 display = Report Failure X
The control panel has failed to
communicate.
Check history #89 to determine the
source:
Report Failure 1 = Phone number 1
Report Failure 2 = Phone number 2
Report Failure 3 = Phone number 3
(remote
programmer)
Report Failure 4 = DS7416i
Communications
fault
#87 display = 2Ph/Bell Fault
#89 display = System Fault 10
a. The dual phone line/bell
supervision module (DS7420i) is
defective or the wiring to the
module is defective.
b. There is no DS7420i or a
DS7420i was removed from the
system.
a. Check the wiring to the module.
b. Enter, then exit programming
mode. This will re-scan the
options bus and clear the
problem.
#87 display = Line 1 Fault
#89 display = System Fault 11
There is a phone line fault on line 1. Check phone line 1 for proper
operation.
#87 display = Line 2 Fault
#89 display = System Fault 12
Check phone line 2 for proper
operation. To monitor only one phone
line, reprogram address 4021.
#87 display = Bell Fault
#89 display = System Fault 13
There is a phone line fault on line 2. Check the bell circuit wiring. Be sure
that the end-of-line resistor is in place.
Place an end-of-line resistor across the
bell terminals if the bell circuit is not
used.
#87 display = Aux. Output Fault
#89 display = System Fault 14
The bell circuit on the DS7420i is open
or shorted.
The auxiliary circuit on the DS7420i is
open or shorted.
Check the auxiliary circuit wiring. Be
sure that the end-of-line resistor is in
place. Place an end-of-line resistor
across the auxiliary terminals if the
auxiliary circuit is not used. Cut the
auxiliary supervision jumper on the
DS7420i to use the auxiliary circuit
without supervision.
#87 display = Aux Power Fault
The auxiliary power output has been
shorted.
Remove wiring from auxiliary power
and check for shorts.
#87 display = Keypad Fault
a. The keypad wiring is defective.
b. A keypad is missing.
c. A keypad was programmed, but is
not intended in this system.
a. Check keypad operation and
wiring.
b. Install a keypad.
c. Remove from programming (3131
to 3138).