5.9.6 Output Programming
Output programming defines the event, area, and type of alarm (burglary or fire) that triggers each of the three
physical outputs on the control panel.
See Section 3.8 Programmable Output Wiring for the location of the physical outputs on the control panel.
See Section 7.2.4 Output Programming for output programming glossary definitions.
See the DX7400XiV4 Wireless Reference Guide (P/N: 4998154790) for additional information.
Address: 2734 to 2736
Data Digits:
Data Digit 1: ____ (see Table 35; see Table 39 for defaults)
Data Digit 2: ____ (see Table 36; default = 3)
Selections: 0 to 9; *0, *1, *3 (hexadecimal values that display as A , B, and D respectively at the keypads)
Table 35: Address 2734 to 2736, Data Digit 1
Select Option Value
Latch on ANY Zone Alarm
1
0
ON during Entry Pre-Alert/Exit Warning 1
On for 10 sec after pressing [System
Reset]
2
ON when system is Armed
2
3
Ground Start 4
System Status (ready to arm) 5
Zone Alarm 6
Zone Alarm delayed by 20 sec 7
Keypad Sounder Output 8
Access Output (10 sec pulse) 9
Keyfob/RF Keypad
3
*0
Panic Duress Output
4
*1
On during battery test *3
1
This includes invisible zones. See Section 7.2.4 Output
Programming for output programming glossary definitions.
2
If Data Digit 1 = 3, see Table 37 for configuring Data Digit
2.
3
If Data Digit 1 = *0, see Table 38 for configuring Data Digit
2.
4
See Section 7.2.4 Output Programming for a description of this
option.
Table 36: Address 2734 to 2736, Data Digit 2
Select Option Value
Disabled 0
Burglar Alarm 1
Fire Alarm 2
Burg and Fire Alarm
3
Table 37: Address 2734 to 2736, Data Digit 2
When Data Digit 1 = 3
Select Option Value
Disabled 0
Armed Full 1
Armed Partial 2
Armed Any
3
Table 38: Address 2734 to 2736, Data Digit 2
When Data Digit 1 = *0
Options RF3334 Value
Disabled 0
Momentary Option Key 1
Toggle Option Key 2
Momentary
1
Auxiliary Key 3
Toggle
1
Auxiliary Key 4
1
Applies on to RF Keyfob (does not apply to RF Keypad).
Table 39: Address 2734 to 2736 Defaults
Output Address Default
Alarm 2734 6 3
Programmable Output 1 2735 3 3
Programmable Output 2 2736 2 3