DS7400XiV4-EXP | Reference Guide | 4.0 Operating Guide EN | 23
Bosch Security Systems | 1/05| 4998154963B
4.5.4 Arming from the Master Keypad
To arm all the Partitions to which you have access:
[PIN] + any Arming Command Sequence. This arms all
the areas to which you have access even if they are
already armed.
To arm only some of the Partitions to which you have
access:
• [PIN][#][#]. This puts you into Single Partition
Mode.
• The first area to which you have access is
displayed: “Ready to Arm. Cafeteria.”
• Enter the Arming Command Sequence you want
for this area.
• [#][#] opens the next area to which you have
access.
• The next area to which you have access is
displayed: "Ready to Arm. Office."
• Enter the Arming Command Sequence you want
for this area.
• After arming any or all areas to which you have
access, you may exit Single Partition Mode by
holding the [*] key for at least two seconds. The
system also exits Single Partition Mode after 40
seconds without a keypad entry.
4.5.5 Disarming from the Master Keypad
To disarm all the Partitions to which you have
access:
• [PIN][Off]. This will disarm all the areas to which
you have access even if they are already disarmed.
To disarm only some of the Partitions to which you
have access:
• [PIN][#][#]. This puts you into Single Partition
Mode.
• The first area to which you have access is
displayed: "Armed. Cafeteria."
• If you wish to disarm this area, enter [Off]. If not,
go to the next step.
• [#][#] opens the next area to which you have
access.
• The next area to which you have access is
displayed: "Armed. Office."
• If you wish to disarm this area, enter [Off]. If not,
go to the next step.
• After disarming any or all areas to which you have
access, you may exit Single Partition Mode by
holding the [*] key for at least two seconds. The
system also exits Single Partition Mode after 40
seconds without a keypad entry.
Commentaires sur ces manuels