5.9.7 Output Partition Assignment
In Output Partition Assignment, each on-board output is assigned to an area. By default, outputs are assigned to
all areas.
See the DX7400XiV4 Wireless Reference Guide (P/N: 4998154790) for additional information.
• Address: 2737 to 2738
• Data Digits:
• Data Digit 1: ____ (see Table 40; see Table 42 for defaults)
• Data Digit 2: ____ (see Table 40 for Address 2737 and Table 41 for Address 2738; see Table 42 for defaults)
• Selections: 0 to 8
Table 40: Address 2737 to 2738, Data Digit 1,
and Address 2737 Data Digit 2
Select Option Value
Belongs to Area 1 0
Belongs to Area 1 1
Belongs to Area 1 2
Belongs to Area 1 3
Belongs to Area 1 4
Belongs to Area 1 5
Belongs to Area 1 6
Belongs to Area 1 7
Follows all Areas
8
Table 41: Address 2738, Data Digit 2
Keyfob Chirp Options Value
Chirp Disabled
0
Bell Output 1
PO1 2
PO2 3
Table 42: Address 2737 to 2738 Defaults
Output Address Default
Alarm 2737 DD1 8
Programmable Output 1 2737 DD2 8
Programmable Output 2 2738 DD1 8
Keyfob Chirp Options 2738 DD2 0