
DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 34
Bosch Security Systems | 1/05| 4998154963B
Step 3: Assigning a Zone Type to the Zone
5.9.3 Zone Programming: Zone Type Program Addresses
In zone type programming, each zone is assigned a zone type to define its physical location as either on-board,
single zone inputs, or multiple zone inputs.
See the DX7400XiV4 Wireless Reference Guide (P/N: 4998154790) for additional information.
The DS7465i occupies two zones. The odd-numbered zone of the zone pair is the input zone. The
even-numbered zone of the zone pair is the output relay. The output follows an output function.
See Table 24 to determine which zones apply to each program address.
• Address: 0415 to 0538
• Data Digit:
• Data Digit 1: ____ (see Table 22; default = 0)
• Data Digit 2: ____ (see Table 23; default = 0)
• Selections: 0 to 3, 5
Table 22: Address 0415 to 0538, Data Digit 1
Odd Zone Number
Select Option Value
Single Zone Input
(Zones 1 to 8 on the control panel,
multiplex contacts, sensors, or a
DS7457/DS7461i)
0
Multiple Zone Input
(any zone that is on a DS7432E, DS7433,
or DS7460i)
If Data Digit 1 = 1, Data Digit 2 must = 2
Multiple Zone Inputs must start on an odd
zone number
1
DS7465i Connections
(the input zone or the output relay on a
DS7465i)
NOTE: If Data Digit 1 = 2, then Data
Digit 2 must = 2.
2
Keyfob
5
1
The DX7465i occupies two zones. the odd-
numbered zone of the zone pair is the input zone.
The even-numbered zone of the zone pair is the
output relay.
Table 23: Address 0415 to 0538, Data Digit 2
Even Zone Number
Select Option Value
Single Zone Input
(Zones 1 to 8 on the control panel,
multiplex contacts, sensors, or a
DS7457/DS7461i)
0
Multiple Zone Input
(any zone that is on a DS7432E, DS7433,
or DS7460i)
If Data Digit 1 = 1, Data Digit 2 must = 2
Multiple Zone Inputs must start on an odd
zone number
1
DS7465i Connections
2
(the input zone or the output relay on a
DS7465i)
NOTE: If Data Digit 1 = 2, then Data
Digit 2 must = 2.
2
Keyfob
5
2
The DX7465i occupies two zones. the odd-
numbered zone of the zone pair is the input zone.
The even-numbered zone of the zone pair is the
output relay.
Commentaires sur ces manuels