Bosch DS7400XiV4-EXP Spécifications Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 144
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 29
Bosch Security Systems | 1/05| 4998154963B
5.7 Understanding the Parameter Option Charts
The programming section of this document presents programming parameters as shown below to identify the
available selections.
Example: Custom Arming Programming
Address: 2725
Data Digit:
Data Digit 1: ____ (see Table 13)
Data Digit 2: ____ (see Table 14)
Default: 0
Selections: 0 to 9, *0 to *5 (hexadecimal values that display as A through F at the keypads)
Table 13: Keyswitch Custom Arming Programming (Address 2725, Data Digit 1)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Bypass Zone Function 1
Bypass Zone Function 2
Bypass Zone Function 3
Bypass Zone Function 4
Table 14: Custom Arming Programming (Address 2725, Data Digit 2)
Selections for Data Digit 2
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Bypass Zone Function 5
Bypass Zone Function 6
Bypass Zone Function 7
Bypass Zone Function 8
Many addresses require two data digit entries. For these addresses, there are two option tables (one table for each
data digit).
To select an option or set of options, select the corresponding value and enter it in the appropriate data digit.
The values under the Selections for Data Digit # heading are displayed across the top of each table. Each value
i
tied to options by a .
s
tied to options by a .
tied to options by a .
t
ied to options by a .
i
ed to options by a .
e
d to options by a .
d
to options by a .
to options by a .
t
o options by a .
o
options by a .
options by a .
o
ptions by a .
p
tions by a .
t
ions by a .
i
ons by a .
o
ns by a .
n
s by a .
s
by a .
by a .
b
y a .
y
a .
a .
a
.
.
.
.
.”
Spaces are provided above the address tables for logging each data digit entry.
The default selection is listed above the table in bulleted form along with the option’s address and selection range.
The numbered cell that corresponds with the option’s default setting is blackened to provide a quick visual
reference. For example, the cells labeled 0 in the example above are this option parameter’s defaults.
Columns that are grayed out are reserved and should not be selected.