DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 54
Bosch Security Systems | 1/05| 4998154963B
5.9.16 Open/Close Report Control Programming
See Section 7.2.12 Open/Close Report Control Programming for Open/Close Report Control Programming glossary
definitions.
• Address: 3149
• Data Digit:
• Data Digit 1: ____ (see Table 68; default = 8)
• Data Digit 2: ____ (see Table 69; default = 0)
• Selections: 0 to 9 (Data Digit 1); 0 or 1 (Data Digit 2)
Table 68: Open/Close Report Control Programming (Address 3149, Data Digit 1)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9
Do not report opens or closes
•
Report opens and closes in Area 1
• • •
• • • • •
Report opens and closes in Area 2
• •
• • • • •
Report opens and closes in Area 3
•
• • • • •
Report opens and closes in Area 4
• • • • •
Report opens and closes in Area 5
• • • •
Report opens and closes in Area 6
• • •
Report opens and closes in Area 7
• •
Report opens and closes in Area 8
•
Report first Area to open and last Area to close
1, 2
•
1
When using this option, all areas should have the same account code.
2
If Data Digit 1 = 9, then Data Digit 2 must = 0.
Table 69: Address 3149, Data Digit 2
Select Option Value
Send Closing and Bypass Reports at close
0
Send Closing and Bypass Reports after exit
delay
1
5.9.17 Open/Close and Zone Report Programming
This section allows you to decide which phone number sends open and close reports, zone alarm, zone restoral,
and zone trouble reports.
• Address: 3151
• Data Digit:
• Data Digit 1 (for Open and Close Reports): ____ (see Table 70)
• Data Digit 2 (for Zone Alarm, Zone Restoral, Zone Trouble, Bypass, Unbypass, and Trouble Restoral
Reports): ____ (see Table 71)
• Default: 0
• Selections: 0 to 3