1. Enter your Master Code and press [6][AWAY]. Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the day, month, year, hour, and minute in DD, MM, YY, HH, MM format (where DD is
the day of the month, MM is the month of the year, YY is the year, HH is the hour of the day,
and MM is the minute of the day) and press [AWAY]. Use 24:00 hour format when
programming the hour of the day. Two beeps sound and the STAY and AWAY indicators are
extinguished. If a long beep sounds, an error occurred when you entered the date and time.
Example
To set the date and time for 1st January 2009 at 10:30 PM, enter:
[2 5 8 0 6][AWAY][0 1 0 1 0 9 2 2 3 0][AWAY]
Walk Test Mode
Walk Test Mode allows you to test detection devices to ensure they are functioning correctly.
Before activating Walk Test Mode, isolate any zones that are not required for testing. Refer to
Isolating zones, page 56 for more information.
To enter Walk Test Mode:
1. Enter the passcode and press [7][AWAY]. Three beeps sound and the STAY and AWAY
indicators flash. The codepad beeps once per sec when Walk Test Mode is active.
2. Unseal and seal the zones to be tested. The codepad sounds one long beep and the horn
speaker sounds one short beep each time a zone is sealed or unsealed.
3. Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns to the disarmed state.
Event Non-Volatile Memory Recall Mode
This function allows you to play back the last 40 system events that occurred. Event Non-
volatile Memory Recall Mode reports all alarms and each arming or disarming of the system
and helps with troubleshooting system faults. The events are shown using the codepad
indicators. The event memory is not lost even with the power supply off.
To enter Event Memory Recall Mode:
Enter your Master Code and press [8][AWAY]. Three beeps sound. The events are played back
by the codepad indicators in reverse chronological order.
Example
If the events occurred in the following order:
Sequence Event
1 System armed in AWAY Mode
2 Alarm in Zone 3
3 Alarm in Zone 4
4 System disarmed
5 System armed in STAY Mode
The alarm memory plays back in this order:
7.2.10
7.2.11
76 en | System Functions Control Panel
2014.07 | 00n | F01U298026 Installation Guide