Turning Outputs On and Off
If an output is programmed for remote operation, you can turn the remote output on or off
using this Master Code function or remotely using the A-Link Software or smartphone
application (RSC).
To use this Master Code function, you must program one or more of the outputs with these
Output Event Types:
Remote control output 1 = Output Event Type 2,8
Remote control output 2 = Output Event Type 2,9
Remote control output 3 = Output Event Type 2,10
Remote control output 4 = Output Event Type 6,2
Remote control output 5 = Output Event Type 6,3
Remote control outputs 6 = Output Event Types 6,4
Remote control outputs 7 = Output Event Types 6,5
Remote control outputs 8 = Output Event Types 6,6
Remote control outputs 9 = Output Event Types 6,7
Remote control outputs 10 = Output Event Types 6,8
Remote control outputs 11 = Output Event Types 6,9
Remote control output 12 = Output Event Type 6,10
To turn an output on from the remote codepad:
1. Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the number of the output (1 to 12) and press [AWAY]. Three beeps sound and the
output turns on.
3. Repeat Step2to turn on another output.
4. Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY
indicators are extinguished.
Example
If Output 2 is programmed as 2,9,1,0,0,0 in Locations 442 to 447, the Master Code holder can
turn on this output by entering:
[2 5 8 0 5][AWAY][2][AWAY][AWAY]
To turn an output off from the remote codepad:
1. Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the number of the output (1 to 12) and press [STAY]. Two beeps sound and the
output turns off.
3. Repeat Step2to turn off another output.
4. Press [AWAY] button to exit from this function. Two beeps sound and the STAY and AWAY
indicators are extinguished.
Setting the Date and Time
Use this function when the date and time must be changed or if the system was powered
down.
If the date and time is not set, the date and time fault appears only when the Auto Arming
Time is programmed in Locations 482 to 485, or when you enter Fault Analysis Mode by
holding down [5].
To set the new date and time:
7.2.8
7.2.9
Control Panel System Functions | en 75