Disable Factory Defaults
This feature prevents the control panel from manually restoring the default settings by the
default button and prevents the use of a programming key to automatically download to the
control panel when the system is disarmed.
Item Location Option Defaul
t
New
Default Options 0900 0 = Button Factory Default Enable
15 = Button Factory Default Disabled
0
Enter the default setting of 0 for Location 900 to restore the control panel to its default
settings. Enter15 for Location 900 to restrict the ability to restore the control panel to its
default settings and to require the Installer Code for future control panel programming.
If the Installer Code is unknown, you must restore the control panel to your Bosch distributor
for exchange. A nominal fee applies for this service.
Notice!
The use of this feature is not recommended.
If you are required to disable the ability restore the control panel to its default settings, a
special procedure eliminates the possibility of accidentally setting this option. You must hold
down the default button on the printed circuit board (PCB) when programming this location.
To prevent manually restoring the default control panel settings:
1. Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s
Programming Mode. Two beeps sound and the remote codepad displays the data
programmed in Location 000. If you are using the remote codepad, the STAY and AWAY
indicators flash to indicate you entered Installer’s Programming Mode.
2. Enter [9 0 0 #] to move to Location 900.
3. Press and hold the default button.
4. Enter [1 5 *] to program 15 into Location 900.
5. Release the default button.
6. Enter [9 6 0 #] to exit from Installer’s Programming Mode. The system returns to the
disarmed state. If you are using a remote codepad, the STAY and AWAY indicators are
extinguished to indicate that the system is disarmed.
If Location 900 is not programmed as 15, do one of the following procedures to restore the
default control panel settings.
To default the control panel settings using the Installer Code:
1. Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s
Programming Mode. Two beeps sound. The STAY and AWAY indicators flash to indicate
you entered Installer’s Programming Mode.
2. Enter [9 6 1 #]. Two beeps sound after the default control panel settings are restored.
3. Enter [9 6 0 #]. The STAY and AWAY indicators stop flashing and the system returns to
the disarmed state.
The control panel default factory settings are restored.
To restore the default control panel settings using the default button:
1. Disconnect the AC MAINS supply and the backup battery from the control panel.