1. Power off the control panel.
2. Set the B426 rotary address switch to 9.
3. Remove the jumper for Tamper and install the jumper for Mode.
4. Change the computer network address to 169.254.1.2.
5. Connect the B426 to the computer with a network cable.
6. Power on the control panel.
Configure for the web
1. From Internet Explorer on the computer, go to http://169.254.1.1. The B426 Login
interface opens. Enter password “B42V2” to access the B426 configuration web interface.
2. Click Factory Default, then click OK to confirm.
3. Click Encryption and Security Settings.
4. Change Web and Automation Security to Enable, then click OK to confirm.
5. Click Maintenance.
6. Change Web Access Enable to Yes,
7. Change Panel Programming Enable to Enable, then click OK to confirm.
8. Click Save and Execute, then click OK to save the changes.
9. Click Logout to log out of the web configuration interface.
10. Power off the control panel.
Restore connection
1. Change the computer network address to its previous value.
2. Remove the cable from the B426 to the computer, and restore the connection in the
diagram.
3. Remove the Mode jumper, and install the Tamper jumper.
4. Turn the rotary address switch to “1”.
Reset the B450/B442 modules to factory default
If the parameters of the B450/B442 are already set to their factory default values, skip the
steps below and go to the next set of steps in Configure A-Link Plus.
1. Power off the control panel.
2. Set the rotary address switch of the B450 to “0”; remove the Tamper jumper.
3. Connect the B450 to the computer with a male to male USB cable.
4. Power on the control panel.
5. Wait until the heartbeat LED on the B450 flashes 3 times per second and the status LED
on the B442 flashes 1 time per second. The flashing indicates the startup process has
completed.
6. Open the “Tera Term” software on the computer and select the serial port named B450
Config Interface.
7. Enter the B450 USB menu interface. Press [ENTER].
8. Enter passcode “B450”. The main menu opens.
9. Enter “5” to select Reset To Factory Default. At the message “Are you sure (Y to default, N
to exit)”, input “Y” to confirm. The interface returns to the main menu.
10. Enter “8” to confirm Save and Exit. Turn off the Tera term.
11. Power off the control panel.
12. Install the Tamper jumper and turn the rotary address switch to 2.
13. Power on the control panel.
Configure A-Link Plus