RF Information
RF Option Bit
1 – Sound Siren on RF Receiver Fail
If this option is selected, the horn speaker, piezo, and strobe operate when the RF receiver
fails to communicate with the control panel.
2 – Sound Siren on RF Tamper/Jamming
If this option is selected, the horn speaker, piezo, and strobe operate when the tamper switch
on the receiver becomes open circuit or the receiver picks up jamming signals from an RF
device.
4 – Unseal Zone that Fails Supervision
If a wireless zone device fails to send a signal within the RF Supervision Time programmed in
Location393 the codepad zone indicator lights as unsealed.
16
Control Panel RF Information | en 141
Installation Guide 2014.07 | 00n | F01U298026