Bosch B450 Guide d'installation Page 103

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 152
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 102
The Sensor Watch Time counter is active only when the control panel is disarmed. If the
system is disarmed for 8 hours a day and the Sensor Watch Time is programmed for 1 day, a
zone programmed for Sensor Watch registers a Sensor Watch Fault if it is not activated while
disarmed within 3 days.
This feature is useful, for example, when someone places objects in the view of a motion
detector, which prevents the detector from picking up movement.
Codepad Lockout Time
Location 478
0 No Lockout
1 to 15 Lockout time (increments of 10 sec)
All codepads are locked out for the programmed time if an invalid code is entered more times
than allowed by the code retry attempts programmed in Location 424. If the Codepad Lockout
Time is programmed as 0, codepad lockout does not occur.
Siren Run Time
Location 479
Default 5
0 No siren time
1 to 15 Siren time in minutes
The Siren Run Time determines how long the horn speaker/siren operates during an alarm.
You can program the Siren Run Time from 0 to 15 min in 1-min intervals.
Siren Sound Rate
Location 480
Default 7
0 Slowest frequency
15 Fastest frequency
The Siren Sound Rate varies the frequency of the siren tone slowest (0) and to fastest (15).
The Siren Sound Rate does not change the frequency of the fire alarm tone.
Auto Arming Pre-Alert Timer
Location 481
0 No Alert time
1 to 15 Alert time (increments of 5 minutes)
10.8
10.9
10.10
10.11
Control Panel System Event Timers | en 103
Installation Guide 2014.07 | 00n | F01U298026
Vue de la page 102
1 2 ... 98 99 100 101 102 103 104 105 106 107 108 ... 151 152