2 – Enable A-Link Call Back
If this option is selected and a callback telephone number is programmed, the remote
programming computer must be connected to the telephone line programmed in the callback
telephone number in Locations 159 to 174.
If this option is not selected, the installer can connect to a customer’s control panel from any
remote location for Upload/Download operations without the control panel calling back to the
remote computer. The customer can initiate a modem call from the codepad by holding down
[6].
4 – Terminate A-Link Connection on Alarm
If an alarm occurs when the control panel is communicating with a remote computer using the
A-Link Plus software over the telephone line, the A-Link session is terminated and the relevant
alarm message is transmitted to the base station receiver.
If an alarm occurs that does not have to be reported to the base station receiver, the session
is not terminated.
Item
Location Default
A-Link Options 180 3
Value Description
1 Enable upload/download using A-Link
2 Enable A-Link callback
4 Terminate A-Link connection on alarm
8 Reserved
Sending reports with the network modules
Program IP Destination with A-Link Plus Software or text codepad
1. In receiver configuration, select Transmission Format as CSVIP , and enter Subscriber ID
Number.
2. In network configuration, select Network Module as Use, do not configure (or "Use and
Configure" through only A-link plus).
3. Enter IP Destination (IP + Port for Receiver 1 or Receiver 2), for example,
192.168.226.17:12000.
4. Enter CSVIP User Name and Password:
– Both user name and password, enter as user name with comma and password with
comma, for example, USER 1, 2580,.
– Only user name, enter as user name with two commas, for example, USER 1,,.
– Only password, enter as comma, followed by password with comma, for example, ,
2580,.
– No user name and password, only enter two commas.
5. Save the changes and download programming data from A-Link Plus to the control panel.
For A-Link Plus, enter 32 case sensitive alphanumeric characters for CSVIP User Name and