Zone
indicator
Fault description Button Zone
indicator
Fault condition
2 Receiver 2 fail
3 IP module 1 fail
4 IP module 2 fail
7 Output and codepad
fail
7 2 Output expander fail
3-6 Codepad fail
8 Keyfob low battery 8 1-16 Keyfob 1 to 16 low battery
Fault descriptions
1 – System Fault
The system FAULT indicator lights when any of the faults listed in the table System FAULT
Indicators below occurs. In Fault Analysis Mode, press [1] to determine the fault that
occurred.
2 – RF Device Low Battery
This fault occurs when any of the RF wireless devices report a low battery condition to the
control panel. While in Fault Analysis Mode, press the [2] key. This displays the zone reporting
the RF Low Battery fault.
3 – Zone Tamper Fail
This fault occurs when any zone with tamper becomes an open or short circuit. Press the [3]
key until. This displays the zone reporting the tamper fail fault.
4 – Sensor Watch Fault
A sensor watch fault registers because one or more detection devices failed to detect any
movement during the disarmed state for the time programmed in Locations 476 and 477(refer
to Sensor Watch Report, page 142). The fault clears once the zone in question detects
movement and resets. Press the [4] key. This displays the zone reporting the sensor watch
fault.
5 – RF Sensor Missing
An RF sensor missing registers because one or more RF detection devices fails to
communicate to the RF radio receiver for the time period programmed in Location 393 RF
Supervision Time. The fault clears once the RF device in question successfully transmits to the
RF radio receiver.
While in Fault Analysis Mode, press the [5] key. This displays the RF detection device
reporting the RF sensor watch fault.
6 – Communication Fail
A communication fail registers when the control panel fails to communicate with the receiving
party (such as a monitoring company, mobile phone). The communication fault clears once the
control panel successfully reports to the receiving party.
A communication fail also registers when network module is disconnected or tampered.
To determine which receiver or module failed to communicate, press the [6] key.
In Fault Analysis Mode, press [6] to show which communication fault occurred: 1 – Receiver 1;
2 – Receiver 2.
7 – Output and Codepad Fail
The output fault registers when the output expander B308 is disconnected or tampered.
6.15
Control Panel System Operations | en 59
Installation Guide 2014.07 | 00n | F01U298026