Event History Readback
This chart explains the procedure for performing an Event History Readback.
The History Buffer stores the last 100 events in memory. The most recent 10 events are stored in non-volitile memory and
will be retained even in the event of a power loss. The DS7447 can display all of these events.
The DS7443S and DS7445 keypads will only display those zones that have alarmed. The DS7443S cannot display zones 7 & 8.
What to DoType of Test
Command
Sequence**
Event History
Readback
The last event to take place will be displayed
on the DS7447 keypad.
For the DS7443S and DS7445 keypads, the zone
LEDs will flash for any zones that have alarmed.
The DS7443S keypads cannot display
zones 7 & 8.
For the DS7447 keypad, scroll
through the events by using the
[9], [6], and [#] keys. See below.
To exit from the Event History
Mode, press the [*] key.
What will Happen
PIN + [#] [8] [9]
** = If in Residential Mode, a PIN is not required for this command.
DS7447 Only: Scrolling through the History Events.
To begin scrolling back through the events, press the [#] key. The [#] key will scroll you back through the history line by line. The [9] key will scroll
you back in reverse chronological order by event. A [6] will scroll you back up through the events (toward the most recent) by event.
Each event consists of two lines or display screens. The first line/screen will be the event title and user. The second line/screen will be the date of
the event or the change being made.
To exit the Event History Mode, press the [*] key or wait 20 seconds and the keypad will exit automatically.