9
Bosch Security Systems 09/07 BLCC500R FTR1.02
Solution 16 i
Quick Start Guide
Copyright © 2007 E&OE
WIRING DIAG R AMS
ZONE 2
N/C
N/C
ZONE 1



Figure 9: N/C No EOL Zone
ZONE 2
ZONE 1
N/C
N/C
ALARM
ALARM



Figure 10: N/C Single EOL Zone
(6K8 EOL)
(3K3 EOL)
N/C
N/C
ALARM
ALARM



ZONE 1
ZONE 9
Figure 11: N/C Split EOL Zone
1
2
TAMPER
(6K8 EOL)
TAMPER
(3K3 EOL)
N/C
N/C



ALARM
ZONE 1
Figure 12: N/C Zone With Tamper
i
Note
The Above diagrams display zone configurations
using Normally-Closed Alarm contacts and
Normally-Open Alarm Contacts. When using
Normally-Open Alarm Contacts you must select
Inverted Seal for each zone in MENU 3-1-8.
A shorted loop is a tamper condition for all EOL
zone configurations.
2
ZONE 2
N/O
N/O
ZONE 1



Figure 13: N/O No EOL Zone
ZONE 2
ZONE 1
N/O
N/O
ALARM
ALARM



Figure 14: N/O Single EOL Zone
(6K8 EOL)
(3K3 EOL)
N/O
N/O
ALARM
ALARM



ZONE 9
ZONE 1
Figure 15: N/O Split EOL Zone
TAMPER
(6K8 EOL)
TAMPER
(3K3 EOL)
N/C
N/O



ALARM
ZONE 1
Figure 16: N/O Zone With Tamper
EOL Resistor Colo urS an d Valu es
Use either the 4 colour, or solid colour resistors supplied.
Orange
Blue
Red
Red
Orange
Grey
3K3
6K8
Brown (+/- 1%)
Brown (+/- 1%)
3K3 =
6K8 =
Orange
Blue
Figure 17: EOL Resistor Colour Chart