27
Bosch Security Systems 09/07 BLCC500R FTR1.02
Solution 16 i
Quick Start Guide
Copyright © 2007 E&OE
PROGR AM LOCATION S
The following section lists all of the programming locations
available in the Solution 16i panel. The default values for
each parameter are shown in grey.
To minimise the size of this guide only one example for
some parameters is shown while the default values for the
other similar parameters are listed in a table.
For example the User Default Table below shows the
default values for Users 1 to 48. Similar tables are used to
show Zone Defaults.
Once in Installer programming mode, you can jump to
and program any location (MENU) by simply entering the
location number followed by the [OK] key.
Enter LOCATION NUMBER + [OK]
Access Pro gramming
User Default Table
Parameter User 1 User 2 - 48
Add PIN 2580
Name User 1 User 2 - 48
Area Assignment
1 1
User Options
Has Master PIN Privileges
Y
Expire PIN Code
Is Arm Only Code
Can Bypass Zones
Y Y
Can Auto Bypass Zones
Y Y
Send ‘Open/Close’ Reports
Y Y
Timer Group
Access Group
Table 17: User Default Programming Options
Access > Commands >
Erase User
MENU 1-0-0
Access > PIN Codes >
Change Own PIN
MENU 1-1-0
Change Other PIN
MENU 1-1-1
Add PIN
MENU 1-1-2
Delete PIN
MENU 1-1-3
View PIN
MENU 1-1-4
Access > Token >
Add Token
MENU 1-2-0
Delete Token
MENU 1-2-1
Token Status
MENU 1-2-2
Access > RF Keyfob >
Add Keyfob
MENU 1-3-0
Delete Keyfob
MENU 1-3-1
Test Keyfob
MENU 1-3-2
Access > User Properties >
User Name
MENU 1-4-0
U s e r 1 N a m e
Use [] and [] Keys To Scroll the Cursor Left and Right. Use Keys [0]
– [9] + [] and [] To Select Characters. When finished press [OK] To
Save. Press [OFF] To Clear From The Current Cursor Position.
Access > Global Properties >
Area Assignment MENU 1-4-1
1 Area 1 Y
2 Area 2 N
3 Area 3 N
4 Area 4 N
Access > User Properties >
User Option MENU 1-4-2
1 Has Master Code Privileges Y
2 Expire PIN Code N
3 Is Arm Only Code N
4 Can Bypass Zones Y
5 Can Auto Bypass Zones Y
6 Always Send Open / Close Reports Y
7 Reserved N
8 Reserved N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Access > User Properties >
Timer Group
MENU 1-4-4
0
Enter 1 - 8 + [OK] To Assign The User To A Timer Group – Can Only
Be Assigned To One Timer Group (0 = No Timer Group)
Access > User Properties >
Access Assignment MENU 1-4-5
1 Access Group 1 N
2 Access Group 2 N
3 Access Group 3 N
4 Access Group 4 N
5 Access Group 5 N
6 Access Group 6 N
7 Access Group 7 N
8 Access Group 8 N
Multiple Groups Can Be Assigned To Each User. Press keys [1] – [8] To
Toggle Groups On/Off, Then Press [OK] To Save.