Bosch Solution 16i Spécifications Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
Solution 16 i
4
Bosch Security Systems 09/07 BLCC500R FTR1.02
Quick Start Guide
Copyright © 2007 E&OE
FEATURE S
Listed below are the main features of the Solution 16i
Control Panel.
Individual Box Tamper Circuit Monitoring
Report Via Email
Telephone Line Busy Tone Detect
RAS Intelli-connect® CLI Caller Line Identification
Daylight Savings
Senior Watch
System Maintenance Interval Reminder
System Weekly Test Reminder
Area Inactivity Interval
Temporary Pin Code
Dual Reporting
Dual Redundant Reporting
Alarm Report Abort/cancel Options
8 Programmable Holiday Calendars
8 Programmable Schedules
16 On-board Zones (Exp To 16 Zones)
Fire Alarm Verification
48 Pin Codes
4 Supervised High Power Digital Outputs
Outputs Expandable to 8 via Relay Module
Supervised Siren Driver
Partitionable To 4 Areas
Dialler Reports SIA, Contact ID, SMS and Email Formats
Supervised LAN Keypads (Maximum 8 Keypads)
Keyswitch Input
256 History Event Memory
EMI / Lightning Transient Protection
ICON interface with Text Prompts
Programmable Via Solution Link Software
Telephone Line Fail Monitor
Time Executed Functions
60 Output Event Types
Exit Restart
Expansion Module Supervision
DTMF Remote Control of Areas and Outputs
Remote Arming
Designed and Manufactured in Australia
Three Year Warranty
OVERV IEW
Zones
The Solution 16i control panel provides up to 16 separate
zones of protection. Zone programming determines the
panel’s response to open/short and tamper conditions on
the zone loop.
Areas
The control panel supports up to 4 separate areas. You can
assign all zones to a single area, or you can assign each
zone to a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Dialler
The control panel has a built-in dialler to send reports to the
receiving party (ie. Security company monitoring station,
mobile phone, SMS etc).
Keypads
You can connect a maximum of 8 fully supervised keypads
to the control panel. Proximity Keypads are also available.
History Log
The control panel can store up to 256 history events from
all 4 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel’s history log via keypad,
serial printer (optional), or by connection of a personal
computer (direct/remote) using the Solution Link upload/
download software.
Programming
You can program the Solution 16i either by a keypad or
using a personal computer using the Solution Link upload/
download software.
Solution Link Version V1.10 or higher is required to program
this panel.
Vue de la page 3
1 2 3 4 5 6 7 8 9 ... 43 44

Commentaires sur ces manuels