Solution 16 i
8
Bosch Security Systems 09/07 BLCC500R FTR1.02
Quick Start Guide
Copyright © 2007 E&OE
Connec tin g Power To Th e Panel
For normal operation, the panel requires both A.C. and DC
power sources. The A.C. source can be provided either by an
external adapter or by an internal transformer depending
on the model and country of sale.
When connecting using the A.C adapter, feed the cable in
to the enclosure and terminate the wires on the removable
terminal block supplied before connection it to the PCB.
If using a 3 wire Adaptor, then the earth wire should also
be terminated onto the terminal block. Always check the
orientation of the terminal block with the PCB markings
before connecting it to the PCB.
Connec tin g The Batter y
The panel is supplied with a set of battey leads to suit
the chosen enclosure. Connect the Red Battery lead to
the Battery (+) terminal and the Black Battery lead to the
Battery (-) terminal on the PCB.
Once terminated onto the PCB connect the other end of
the leads to the battery paying attention to the polarity.
A.C. mains Transfo rme r O pti on
On models with an internal transformer, a suitable mains
power cord must be installed between the transformer and
the A.C Mains supply. See Figure 8 below. This must be
completed by a suitably qualified electrician according to
the applicable wiring standards and regulations.
i
Note
For permanently connected equipment, a readily
accessible disconnect device such as an A.C. Mains
power outlet or mains switch shall be installed in a
location near the equipment, for connection of the
mains power cord.
Next connect the transformer output wires (red) to the
removable terminal block supplied and then connect it
to the PCB. Always check the orientation of the terminal
block with the PCB markings before connecting.
Figure 8: Internal Transformer Connection Diagram
Pa nel LE D I n dic ator s
The Solution 16i PCB has two LED indicators (Dialler and
Status LED’s) which display the following information.
Condition
Meaning
Off Offline
On On Line (Dialling/Answered)
Flashing Incoming Call
Table 2: Dialler Indicator LED
Condition
Meaning
Off Error
On Error
Flash Once Every 2 Seconds
OK
Flash Fast AC or Battery Trouble
Table 3: Status Indicator LED
i
Note
During factory defaulting the Status and Dialler LED
indicators will flash alternatively for approximately
15 seconds.