Solution 16 i
Quick Start Guide
Copyright © 2007 E&OE
i
Note
The display will flash promting you to enter the
required data value.
d=01
Figure 28: List Option Programming Display
Progra mmi ng The Cl ock
Clock programming requires the following information
to be entered, dd mm yy hh mm. To accept the currently
programmed data for any field, simply press the [
] to
move to the next field.
Enter location 7-1-0 followed by the [OK] key. The keypad
will display the currently programmed day of the month.
To change, enter the new day of the month. The system will
automatically move to the month field.
dd=19
To change, enter the new month of the year. The system
will automatically move to the year field.
MM=05
To change, enter the new year. The system will automatically
move to the hour field.
yy=07
To change, enter the hour of the day in 24hr format. The
system will automatically move to the minute field.
To change, enter the minute of the hour followed by the
[OK] key to exit.
i
Note
Pressing OK on any field will accept all currently
programmed date and time values. Time is
programmed in 24 hr format.
GE T TI NG STAR TED BACK TO B ASE
The following steps are the mimimum requirements to get
the system reporting back to base. Examples assume the
panel is disarmed with no alarms and starting from factory
default settings.
1) Enter Program mode.
[1234 + MENU]
2) Set Time and Date.
[MENU 7-1-0]
3) Change Default Installer PIN.
[MENU 1-5-2]
4) Change Default Master Code PIN.
[MENU 1-1-1]
5) Enter Account (client) Number, Area 1.
[MENU 2-2-0]
6) Enter Base Primary Telephone Number.
[MENU 5-1-1]
7) Enter Base Secondary Telephone Number.
[MENU 5-1-2]
8) Hold Down MENU Key To Exit.
SERVI CE MOD E
Service mode when activated disables dialler reporting,
prevents all alarms and prevents all users from arming the
system.
To Turn Service Mode ON
1) Enter Program Mode.
[1234 + MENU]
2) Enter,
[MENU 7-0-8]
3) The display will show IS OFF if service mode is off
or IS ON if service mode is on.
4) Press the On or OFF key to change the service
mode state then press [OK] to exit.
SERViC
i
Note
Keypads will display SErVIC on the screen when
service mode is active.
DEFAULTING THE SYST EM
Defaulting the system will reset all programming options
back to the factory default setting. All programming
information will be erased.
To Hardware Default
1) Remove All Power To The System. AC and
Battery.
2) Press and Hold The Default Push Button
Down Then Apply Power To The System.
3) Release Button, The Panel Will Reset And
Revert To Normal Operation When Default Is
Complete.
To Software Default
1) Enter Program Mode.
[1234 +MENU]
2) Select Factory Default Option.
[MENU 7-0-4)