Solution 16 i
14
Bosch Security Systems 09/07 BLCC500R FTR1.02
Quick Start Guide
Copyright © 2007 E&OE
Term ina l D esc rip tio ns
Name Description
1 Earth
Earth wire from this terminal is connected
to the Mains earth.
2
3
~ (AC)
~ (AC)
Connection of the 16-18V A.C. 50-60 Hz
adapter or internal transformer.
4
5
BAT (-)
BAT (+)
Negative and positive connections to the
stand-by battery. 12 VDC / 7.2AH
6
7
8
9
+12 V
+12 V
GND
GND
These terminals are used to power
detectors and other accessory devices.
(750mA Fused)
10
11
LAN +
LAN -
These terminals are used to power LAN
modules and devices. (750 mA Fused)
12 LAN A
Connect the LAN A data terminal of any
LAN device (eg. Keypads, expansion
boards) to this terminal. The control
panel supports up to 300 m of 24/0.20
(18 AWG) wire on these terminals.
13 LAN B
Connect the LAN B data terminal of any
LAN device (eg. Keypads, expansion
boards) to this terminal. The control
panel supports up to 300 m of 24/0.20
(18 AWG) wire on these terminals.
14 COMM+
Common positive terminal for system
outputs. This terminal is 2.5A PTC Fuse
protected.
15
16
17
18
OUT 1
OUT 2
OUT 3
OUT 4
Fully supervised programmable, open
collector outputs capable of driving
(sink) loads up to 1 amp for sirens, strobes
etc.
19 INPUT
Programmable Input for RF Receivers,
Keyswitch and other devices.
20 ZN 1 Zone 1 and 9 sensor loop input (+).
21 GND Common (-) for Zone 1 & 2 sensor loop.
22 ZN 2 Zone 2 and 10 sensor loop input (+).
23 ZN 3 Zone 3 and 11 sensor loop input (+).
24 GND Common (-) for Zone 3 & 4 sensor loop.
25 ZN 4 Zone 4 and 12 sensor loop input (+).
26 ZN 5 Zone 5 and 13 sensor loop input (+).
27 GND Common (-) for Zone 5 & 6 sensor loop.
28 ZN 6 Zone 6 and 14 sensor loop input (+).
29 ZN 7 Zone 7 and 15 sensor loop input (+).
30 GND Common (-) for Zone 7 & 8 sensor loop.
31 ZN 8 Zone 8 and 16 sensor loop input (+).
32
33
IN
IN
These terminals are used to connect the
telephone line from the street.
34
35
OUT
OUT
These terminals are used to connect the
premises telephones.
Table 4: Terminal Block Descriptions
i
Note
The maximum combined continuous current draw
from the +12V, LAN + and COMM+ terminals must
not exceed 1 Amp
Bo ard Co nne c tor s
Connector Description
Service
This socket allow you to connect a service
Keypad to the panel during installation.
Tamper
This socket is used to connect the cabinet
tamper switch to the panel.
Default
This push button is used to reset the con-
trol panel back to factory default and to
enable Direct Link Programming Mode.
Voice
Module
This is used to connect the optional Voice
Command Module (CM100).
Direct Link
Port
This socket is used to connect the Direct
Link Interface (P/N CM900) or the Flash
Programmer Interface (P/N CM901) to the
panel.
Telco
This is a RJ12 6P/4C connector that allows
you to connect the control panel to the
PSTN telephone line.
Expansion
Port
Used to connect addition modules to the
control panel. eg TCP/IP interface.
LAN Term Used to terminate the RS485 LAN.
Table 5: Board Connector Descriptions
ABOUT THE KEYPAD
The ICON Keypad has 20 keys or buttons. The buttons allow
you to input instructions and navigate the menu screens
as required. Some buttons have a secondary function
which is activated by holding them down for two seconds.
Each buttons function is described below.
Keypad Button Fun c tions
Key Description
to
The numeric keys allow you to enter
numbers when required.
Use the [MENU] and the numeric keys
to enter commands. The [MENU] key
is also used to go back one level when
navigating through menus or to exit a
programming location without saving
changes.
The [ON] key allows you to turn an area
or output on. To turn all areas on at the
same time when the system has been
partitioned, press and hold the [ON]
key for two seconds.
The [PART] key allows you to turn an
area Part On. This key can also be used
to bypass a zone or multiple zones when
you press and hold for two seconds.