SETTINGS
6 720 806 768 (2013/02)50
20.4 ENERGY MEASUREMENTS
> Generated energy
This displays Generated energy in kWh divided into Heating and Hot
water.
> Consumption electric additional heat
This displays Consumption electric additional heat in kWh divided into
Heating and Hot water.
20.5 TIMERS
The control unit shows the timers that are in operation. There are a
number of timers for, e.g., delays of different types, but also for extra hot
water, hot water peak, etc. A number of these times are set under
customer or installer, whereas others have a set factory value which
cannot be changed. Level shows at what level the setting can be made.
0 = Customer, 1 = Installer, 3 = Factory.
*)
Between compressors/heat pumps
Energy is measured per compressor; the calculated
results are added prior to being displayed.
Timers Setting F value Level
Extra hot water Extra hot water duration 0h 0, 1
Hot water peak time for warm-keeping Hot water\Hot water peak\Time for warm-keeping 1.0h 1
Alarm mode delay 1.0h 3
Party Party ( ) 0h 0
Operating time for heating at hot water demand Room temperature\General\Maximum operating time for heating
at hot water demand
20min 0
Hot water, operating time at heating demand Hot water\Maximum operating time for hot water at heating
demand
30 min 0
Heat pump x timers
> Compressor start delay 10min 3
> Compressor start delay groundwater Installer\General\Groundwater\Compressor start delay 0s 1
> G2 heat carrier pump stop delay 5min 3
> Block low pressure switch 150s 3
> Compressor working area timers
>> Block after hot water production 120s 3
>> Delay after temporary stop 60min 3
>> Block after low outdoor temperature 30 min 3
Additional heat timers
> Additional heat start delay Additional heat\Additional heat general\Start delay 120min 1
> Additional heat start delay after high outdoor temperature 30 min 3
> Delay mixing valve control after additional heat start Additional heat\Mixed additional heat\Delay mixing valve control
after additional heat start
20min 1
> Additional heat program activation delay after low outdoor
temperature
15min 3
Delay before change over to summer operation Room temperature\General\Summer/winter operation\Delay
before change over to summer operation
4h 1
Delay before change over to winter operation Room temperature\General\Summer/winter operation\Delay
before change over to winter operation
4h 1
Shut down protection during change over from hot water to heating 300s 3
Heating start delay
*)
3min -
Heating stop delay
*)
3min -
Table 99 Timers